78519
– GEM100TRILC3-5
GE HID Distributor Replacement Kit Magnetic Core & Coil Ballast
• Magnetic ballast construction ideal for a wide variety of lighting applications.
• Precision-wound coils, ensuring even heat dissipation and the highest electrical integrity.
• Distributor replacement kit contains the appropriate core & coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement
• Tri-Tap ballast (120, 277, 347)
| GENERAL CHARACTERISTICS |
| Category |
High Intensity Discharge |
| Primary Application |
1- 100w MH M 90 or M140 Tri Tap (120/277/347V)
|
| Ballast Type |
Magnetic - Core & Coil |
| Type |
Replacement kit |
| Starting Method |
Pulse start |
| Line Voltage Regulation (+/-) |
10 % |
| Ambient Temperature (MAX) |
200 °C(392 °F) |
| Case Temperature (MAX) |
105 °C(221 °F) |
| Ballast Factor |
Normal |
| Circuit Type |
HX-HPF |
| Insulation Class |
200C |
| Enclosure Type |
None |
| Type of Capacitor |
Oil filled |
| Capacitance |
12 µF |
| Capacitor Temperature Rating |
105 °C(221 °F) |
| Distance to Lamp (MAX) |
5 ft |
| ELECTRICAL CHARACTERISTICS |
| Supply Current Frequency (MIN) |
60.0 Hz |
| Supply Current Frequency |
60 Hz |
| Voltage (MIN) |
300.0 |
| PRODUCT INFORMATION |
| Product Code |
78519 |
| Description |
GEM100TRILC3-5 |
| Standard Package |
Master |
| Standard Package GTIN |
10043168785195 |
| Standard Package Quantity |
6 |
| Sales Unit |
Distributor Kit |
| No Of Items Per Sales Unit |
1 |
| No Of Items Per Standard Package |
6 |
| UPC |
043168785198 |
|
|
| DIMENSIONS |
| Weight |
5.43 lb |
| Exit Type |
Side |
| Nominal Length |
2.7000 in(68.58 mm) |
View Larger
|
| SPECIFICATIONS BY LAMP & LINE VOLTAGE |
| Lamp |
# of Lamps |
Specifications by Line Voltage |
|
M140
|
1 |
|
277 |
120 |
347 |
|
|
System Wattage (W) |
128 | 128 | 128 |
| Nominal Current |
0.50 A | 1.16 A | 0.40 A |
| Ballast Factor |
1 | 1 | 1 |
| Ballast Efficiency |
0.781 | 0.781 | 0.781 |
| Drop Out Voltage |
235 V | 102 V | 295 V |
| Power factor (>=) % |
90 | 90 | 90 |
| Min. starting temperature |
40 40.0 / 4 | 40 40.0 / 4 | 40 40.0 / 4 |
| Fuse rating |
1.5 | 3.5 | 1 |
| |
|
|
|
|
|
|
M90
|
1 |
|
277 |
120 |
347 |
|
|
System Wattage (W) |
128 | 128 | 128 |
| Nominal Current |
0.50 A | 1.16 A | 0.40 A |
| Ballast Factor |
1 | 1 | 1 |
| Ballast Efficiency |
0.781 | 0.781 | 0.781 |
| Drop Out Voltage |
235 V | 102 V | 295 V |
| Power factor (>=) % |
90 | 90 | 90 |
| Min. starting temperature |
40 40.0 / 4 | 40 40.0 / 4 | 40 40.0 / 4 |
| Fuse rating |
1.5 | 3.5 | 1 |
| |
|
|
|
|
|
Dimming Levels78519 - l_ProductName The following dimming levels apply when paired with: | Dimming Levels | Line Volts | System Watts | Nom. Line Current | System Ballast Factor | Ballast Efficacy Factor | Power Factor | Crest Factor | THD% | Min. Starting Temp | | 347 | 128.0 | 0.4 A | 1.0 | | 90 | | | 40.0 / 4 |
Dimming Levels78519 - l_ProductName The following dimming levels apply when paired with: | Dimming Levels | Line Volts | System Watts | Nom. Line Current | System Ballast Factor | Ballast Efficacy Factor | Power Factor | Crest Factor | THD% | Min. Starting Temp | | 120 | 128.0 | 1.16 A | 1.0 | | 90 | | | 40.0 / 4 |
Dimming Levels78519 - l_ProductName The following dimming levels apply when paired with: | Dimming Levels | Line Volts | System Watts | Nom. Line Current | System Ballast Factor | Ballast Efficacy Factor | Power Factor | Crest Factor | THD% | Min. Starting Temp | | 277 | 128.0 | 0.5 A | 1.0 | | 90 | | | 40.0 / 4 |
Dimming Levels78519 - l_ProductName The following dimming levels apply when paired with: | Dimming Levels | Line Volts | System Watts | Nom. Line Current | System Ballast Factor | Ballast Efficacy Factor | Power Factor | Crest Factor | THD% | Min. Starting Temp | | 347 | 128.0 | 0.4 A | 1.0 | | 90 | | | 40.0 / 4 |
Dimming Levels78519 - l_ProductName The following dimming levels apply when paired with: | Dimming Levels | Line Volts | System Watts | Nom. Line Current | System Ballast Factor | Ballast Efficacy Factor | Power Factor | Crest Factor | THD% | Min. Starting Temp | | 277 | 128.0 | 0.5 A | 1.0 | | 90 | | | 40.0 / 4 |
Dimming Levels78519 - l_ProductName The following dimming levels apply when paired with: | Dimming Levels | Line Volts | System Watts | Nom. Line Current | System Ballast Factor | Ballast Efficacy Factor | Power Factor | Crest Factor | THD% | Min. Starting Temp | | 120 | 128.0 | 1.16 A | 1.0 | | 90 | | | 40.0 / 4 |
Safety & Performance
|
cUL Listed |
 |
UL Listed |
Cautions & Warnings
78519 GE HID Distributor Replacement Kit Magnetic Core & Coil Ballast
Warning
- Risk of Electric Shock
- Turn power off before servicing--see instructions.
See list of cautions & warnings.
NOTES
- Kit contains the appropriate core & coil with color coded leads, a properly rated capacitor and ignitor (if required) and all other components required for ballast replacement
|
|
WARRANTY INFORMATION
GE Lighting warrants to the purchaser that each ballast will be free from defects in material or workmanship for period as defined in the attached documents from the date of manufacture when properly installed and under normal conditions of use.
Download full warranty
|
|